Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Acta Crystallogr D Struct Biol ; 79(Pt 7): 569-584, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37326585

RESUMO

Understanding how structure and function meet to drive biological processes is progressively shifting the cryoEM field towards a more advanced analysis of macromolecular flexibility. Thanks to techniques such as single-particle analysis and electron tomography, it is possible to image a macromolecule in different states, information that can subsequently be extracted through advanced image-processing methods to build a richer approximation of a conformational landscape. However, the interoperability of all of these algorithms remains a challenging task that is left to users, preventing them from defining a single flexible workflow in which conformational information can be addressed by different algorithms. Therefore, in this work, a new framework integrated into Scipion is proposed called the Flexibility Hub. This framework automatically handles intercommunication between different heterogeneity software, simplifying the task of combining the software into workflows in which the quality and the amount of information extracted from flexibility analysis is maximized.


Assuntos
Algoritmos , Software , Microscopia Crioeletrônica/métodos , Processamento de Imagem Assistida por Computador/métodos , Conformação Molecular , Substâncias Macromoleculares/química
2.
Rev. int. med. cienc. act. fis. deporte ; 22(87): 535-549, sept. 2022. tab
Artigo em Espanhol | IBECS | ID: ibc-211087

RESUMO

El Judo es un deporte estático alto y dinánimo bajo, con alto riesgo de colisión corporal y lesional. El objetivo de este trabajo es determinar la incidencia lesional y comparar los distintos factores de riesgo que pudieran estar implicados. Se estudió a un total de 86 judocas del Equipo Nacional de Judo español (ENJE) durante dos períodos olímpicos: Beijing-Río. Se produjeron 2028 lesiones con mayor frecuencia en miembro inferior, sin diferencias significativas por sexo. Se objetivó mayor incidencia lesional cuando el judoca era tori y durante el momento del entrenamiento. No existen trabajos previos que comparen estos parámetros, por lo que este estudio aporta datos que pueden ser utilizados para prevenir los riesgos de lesión en el judo de alta competición. (AU)


Judo is a high static and low dynamic sport, with a high risk of bodily and injury collision. The objective of this work is to determine the incidence of injury and to compare the different risk factors that may be involved. A total of 86 judokas from the Spanish National Judo Team (ENJE) were studied during two Olympic periods: Beijing-Rio. 2028 injuries occurred more frequently in the lower limb, without significant differences by sex. A higher incidence was observed in tori judoka and during training. No existing work has examined these parameters. The present study provides data that can be used to reduce the risk of injury in elite judokas. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Artes Marciais/lesões , Traumatismos em Atletas , Estudos Retrospectivos , Espanha , Extremidade Inferior , Desempenho Atlético
3.
J Struct Biol ; 214(3): 107872, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35660516

RESUMO

Image processing in cryogenic electron tomography (cryoET) is currently at a similar state as Single Particle Analysis (SPA) in cryogenic electron microscopy (cryoEM) was a few years ago. Its data processing workflows are far from being well defined and the user experience is still not smooth. Moreover, file formats of different software packages and their associated metadata are not standardized, mainly since different packages are developed by different groups, focusing on different steps of the data processing pipeline. The Scipion framework, originally developed for SPA (de la Rosa-Trevín et al., 2016), has a generic python workflow engine that gives it the versatility to be extended to other fields, as demonstrated for model building (Martínez et al., 2020). In this article, we provide an extension of Scipion based on a set of tomography plugins (referred to as ScipionTomo hereafter), with a similar purpose: to allow users to be focused on the data processing and analysis instead of having to deal with multiple software installation issues and the inconvenience of switching from one to another, converting metadata files, managing possible incompatibilities, scripting (writing a simple program in a language that the computer must convert to machine language each time the program is run), etcetera. Additionally, having all the software available in an integrated platform allows comparing the results of different algorithms trying to solve the same problem. In this way, the commonalities and differences between estimated parameters shed light on which results can be more trusted than others. ScipionTomo is developed by a collaborative multidisciplinary team composed of Scipion team engineers, structural biologists, and in some cases, the developers whose software packages have been integrated. It is open to anyone in the field willing to contribute to this project. The result is a framework extension that combines the acquired knowledge of Scipion developers in close collaboration with third-party developers, and the on-demand design of functionalities requested by beta testers applying this solution to actual biological problems.


Assuntos
Tomografia com Microscopia Eletrônica , Software , Algoritmos , Microscopia Crioeletrônica/métodos , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes
4.
Acta Crystallogr D Struct Biol ; 78(Pt 4): 410-423, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35362465

RESUMO

Cryo-electron microscopy (cryoEM) has become a well established technique to elucidate the 3D structures of biological macromolecules. Projection images from thousands of macromolecules that are assumed to be structurally identical are combined into a single 3D map representing the Coulomb potential of the macromolecule under study. This article discusses possible caveats along the image-processing path and how to avoid them to obtain a reliable 3D structure. Some of these problems are very well known in the community. These may be referred to as sample-related (such as specimen denaturation at interfaces or non-uniform projection geometry leading to underrepresented projection directions). The rest are related to the algorithms used. While some have been discussed in depth in the literature, such as the use of an incorrect initial volume, others have received much less attention. However, they are fundamental in any data-analysis approach. Chiefly among them, instabilities in estimating many of the key parameters that are required for a correct 3D reconstruction that occur all along the processing workflow are referred to, which may significantly affect the reliability of the whole process. In the field, the term overfitting has been coined to refer to some particular kinds of artifacts. It is argued that overfitting is a statistical bias in key parameter-estimation steps in the 3D reconstruction process, including intrinsic algorithmic bias. It is also shown that common tools (Fourier shell correlation) and strategies (gold standard) that are normally used to detect or prevent overfitting do not fully protect against it. Alternatively, it is proposed that detecting the bias that leads to overfitting is much easier when addressed at the level of parameter estimation, rather than detecting it once the particle images have been combined into a 3D map. Comparing the results from multiple algorithms (or at least, independent executions of the same algorithm) can detect parameter bias. These multiple executions could then be averaged to give a lower variance estimate of the underlying parameters.


Assuntos
Imageamento Tridimensional , Viés , Consenso , Microscopia Crioeletrônica/métodos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes
5.
J Vis Exp ; (171)2021 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-34125107

RESUMO

Cryo-electron microscopy has become one of the most important tools in biological research to reveal the structural information of macromolecules at near-atomic resolution. In single-particle analysis, the vitrified sample is imaged by an electron beam and the detectors at the end of the microscope column produce movies of that sample. These movies contain thousands of images of identical particles in random orientations. The data need to go through an image processing workflow with multiple steps to obtain the final 3D reconstructed volume. The goal of the image processing workflow is to identify the acquisition parameters to be able to reconstruct the specimen under study. Scipion provides all the tools to create this workflow using several image processing packages in an integrative framework, also allowing the traceability of the results. In this article the whole image processing workflow in Scipion is presented and discussed with data coming from a real test case, giving all the details necessary to go from the movies obtained by the microscope to a high resolution final 3D reconstruction. Also, the power of using consensus tools that allow combining methods, and confirming results along every step of the workflow, improving the accuracy of the obtained results, is discussed.


Assuntos
Processamento de Imagem Assistida por Computador , Imagem Individual de Molécula , Microscopia Crioeletrônica , Substâncias Macromoleculares , Fluxo de Trabalho
6.
J Struct Biol ; 213(1): 107695, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33421545

RESUMO

The presence of preferred orientations in single particle analysis (SPA) by cryo-Electron Microscopy (cryoEM) is currently one of the hurdles preventing many structural analyses from yielding high-resolution structures. Although the existence of preferred orientations is mostly related to the grid preparation, in this technical note, we show that some image processing algorithms used for angular assignment and three-dimensional (3D) reconstruction are more robust than others to these detrimental conditions. We exemplify this argument with three different data sets in which the presence of preferred orientations hindered achieving a 3D reconstruction without artifacts or, even worse, a 3D reconstruction could never be achieved.


Assuntos
Microscopia Crioeletrônica/métodos , Imagem Individual de Molécula/métodos , Algoritmos , Artefatos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos
7.
J Investig Allergol Clin Immunol ; 31(4): 316-321, 2021 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-31983676

RESUMO

BACKGROUND AND OBJECTIVE: Eosinophilic esophagitis (EoE) is a chronic and isolated inflammation of the esophagus characterized by a marked infiltration of eosinophilic leukocytes. Diagnosis and course of the disease are based exclusively on histopathology. Therefore, patients must undergo several esophageal biopsies, implying a risk associated with the procedure and considerable use of resources. Objective: The presence of active circulating eosinophils, which are quantifiable through the expression of specific cellular activation proteins in their membrane, could be consistent with histopathological findings, which are currently the only valid parameters in studies on EoE. METHODS: The activity of peripheral blood eosinophils from patients with EoE was analyzed by identifying 5 surface molecules (CD69, IL- 5Rα, CD44, ICAM-1, CD63), which are seen to be expressed by the active eosinophils in flow cytometry. The results were compared with the infiltrate of eosinophils present in patients' esophageal biopsies. RESULTS: ICAM-1 levels decreased significantly in patients with active EoE compared with nonactive EoE patients, allergic patients, and healthy controls. In patients with EoE, an inverse correlation was observed between the number of eosinophils in the esophageal biopsy and the percentage of ICAM-1 expression in peripheral blood eosinophils. No differences were observed for the remaining molecules studied. CONCLUSION: Expression of ICAM-1 in blood eosinophils could be a useful noninvasive marker for the diagnosis and assessment of patients with EoE.


Assuntos
Células Sanguíneas/imunologia , Esofagite Eosinofílica/imunologia , Eosinófilos/imunologia , Esôfago/imunologia , Molécula 1 de Adesão Intercelular/metabolismo , Adolescente , Adulto , Biomarcadores/metabolismo , Biópsia , Regulação para Baixo , Feminino , Humanos , Molécula 1 de Adesão Intercelular/genética , Masculino , Pessoa de Meia-Idade , Adulto Jovem
8.
J. investig. allergol. clin. immunol ; 31(4): 316-321, 2021. tab, graf
Artigo em Inglês | IBECS | ID: ibc-215223

RESUMO

Background: Eosinophilic esophagitis (EoE) is a chronic and isolated inflammation of the esophagus characterized by a marked infiltration of eosinophilic leukocytes. Diagnosis and course of the disease are based exclusively on histopathology. Therefore, patients must undergo several esophageal biopsies, implying a risk associated with the procedure and considerable use of resources. Objective: The presence of active circulating eosinophils, which are quantifiable through the expression of specific cellular activation proteins in their membrane, could be consistent with histopathological findings, which are currently the only valid parameters in studies on EoE. Methods: The activity of peripheral blood eosinophils from patients with EoE was analyzed by identifying 5 surface molecules (CD69, IL- 5Rα, CD44, ICAM-1, CD63), which are seen to be expressed by the active eosinophils in flow cytometry. The results were compared with the infiltrate of eosinophils present in patients’ esophageal biopsies. Results: ICAM-1 levels decreased significantly in patients with active EoE compared with nonactive EoE patients, allergic patients, and healthy controls. In patients with EoE, an inverse correlation was observed between the number of eosinophils in the esophageal biopsy and the percentage of ICAM-1 expression in peripheral blood eosinophils. No differences were observed for the remaining molecules studied. Conclusion: Expression of ICAM-1 in blood eosinophils could be a useful noninvasive marker for the diagnosis and assessment of patients with EoE (AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Células Sanguíneas/imunologia , Esofagite Eosinofílica/sangue , Esofagite Eosinofílica/imunologia , Molécula 1 de Adesão Intercelular/sangue , Molécula 1 de Adesão Intercelular/metabolismo , Biomarcadores/sangue , Regulação para Baixo
9.
J Struct Biol X ; 4: 100016, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32647820

RESUMO

Resolution (global and local) is one of the most reported metrics of quality measurement in Single Particle Analysis (SPA). However, in electron tomography, the situation is different and its computation is not straightforward. Typically, resolution estimation is global and, therefore, reduces the assessment of a whole tomogram to a single number. However, it is known that tomogram quality is spatially variant. Still, up to our knowledge, a method to estimate local quality metrics in tomography is lacking. This work introduces MonoTomo, a method developed to estimate locally in a tomogram the highest reliable frequency component, expressed as a form of local resolution. The fundamentals lie in a local analysis of the density map via monogenic signals, which, in analogy to MonoRes, allows for local estimations. Results with experimental data show that the local resolution range that MonoTomo casts agrees with reported resolution values for experimental data sets, with the advantage of providing a local estimation. A range of applications of MonoTomo are suggested for further exploration.

10.
J Chem Inf Model ; 60(5): 2533-2540, 2020 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-31994878

RESUMO

Advances in cryo-electron microscopy (cryo-EM) have made it possible to obtain structures of large biological macromolecules at near-atomic resolution. This "resolution revolution" has encouraged the use and development of modeling tools able to produce high-quality atomic models from cryo-EM density maps. Unfortunately, many practical problems appear when combining different packages in the same processing workflow, which make difficult the use of these tools by non-experts and, therefore, reduce their utility. We present here a major extension of the image processing framework Scipion that provides inter-package integration in the model building area and full tracking of the complete workflow, from image processing to structure validation.


Assuntos
Processamento de Imagem Assistida por Computador , Software , Microscopia Crioeletrônica , Fluxo de Trabalho
11.
J Struct Biol ; 209(3): 107447, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31911170

RESUMO

The analysis of structure factors in 3D cryo-EM Coulomb potential maps and their "enhancement" at the end of the reconstruction process is a well-established practice, normally referred to as sharpening. The aim is to increase contrast and, in this way, to help tracing the atomic model. The most common way to accomplish this enhancement is by means of the so-called B-factor correction, which applies a global filter to boost high frequencies with some dampening considerations related to noise amplification. The results are maps with a better visual aspect and a quasiflat spectrum at medium and high frequencies. This practice is so widespread that most map depositions in the Electron Microscopy Data Base (EMDB) only contain sharpened maps. Here, the use in cryoEM of global B-factor corrections is theoretically and experimentally analyzed. Results clearly illustrate that protein spectra present a falloff. Thus, spectral quasi-flattening may produce protein spectra with distortions when compared with experimental ones, this fact, combined with the practice of reporting only sharpened maps, generates a sub-optimal situation in terms of data preservation, reuse and reproducibility. Now that the field is more advanced, we put forward two suggestions: (1) to use methods which keep more faithfully the original experimental signal properties of macromolecules when "enhancing" the map, and (2) to further stress the need to deposit the original experimental maps without any postprocessing or sharpening, not only the enhanced maps. In the absence of access to these original maps data is lost, preventing their future analysis with new methods.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Substâncias Macromoleculares/ultraestrutura , Microscopia Eletrônica/normas , Conformação Proteica , Microscopia Crioeletrônica , Modelos Moleculares , Software
12.
Mar Pollut Bull ; 143: 33-41, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31789163

RESUMO

The effects of CO2-related acidification on two crustacean populations, the isopod Cyathura carinata and the amphipod Elasmopus rapax, were studied. Three pH levels were tested: artificial seawater without CO2 injection and two levels of reduced pH. Even though RNA:DNA ratio was reduced for both species, no statistical significant differences were found between the control and the treatments. Both species experienced a reduction in survivorship, longevity and the body length of surviving animals; although the impairment observed in E. rapax was more severe than in C. carinata. The long life span isopod and the short life span amphipod experienced a high degree of impairment in the reproduction, likely due to the reallocation of resources from reproduction to body maintenance and increasing survival by postponing the brood production. Regardless of the underlying processes and the energetic pathways, both experienced failure to reproduce, which could lead to the local extinction of these species.


Assuntos
Anfípodes/fisiologia , Dióxido de Carbono , Isópodes/fisiologia , Reprodução/fisiologia , Água do Mar/química , Anfípodes/anatomia & histologia , Anfípodes/genética , Animais , Tamanho Corporal , Ecotoxicologia , Sedimentos Geológicos/química , Concentração de Íons de Hidrogênio , Isópodes/anatomia & histologia , Isópodes/genética , Mortalidade , Especificidade da Espécie
13.
Acta Crystallogr D Struct Biol ; 75(Pt 10): 882-894, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31588920

RESUMO

Electron microscopy of macromolecular structures is an approach that is in increasing demand in the field of structural biology. The automation of image acquisition has greatly increased the potential throughput of electron microscopy. Here, the focus is on the possibilities in Scipion to implement flexible and robust image-processing workflows that allow the electron-microscope operator and the user to monitor the quality of image acquisition, assessing very simple acquisition measures or obtaining a first estimate of the initial volume, or the data resolution and heterogeneity, without any need for programming skills. These workflows can implement intelligent automatic decisions and they can warn the user of possible acquisition failures. These concepts are illustrated by analysis of the well known 2.2 Šresolution ß-galactosidase data set.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia Eletrônica/métodos , Imagem Individual de Molécula/métodos , Software , Automação , beta-Galactosidase/química
14.
Acta Crystallogr F Struct Biol Commun ; 75(Pt 1): 19-32, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30605122

RESUMO

Single-particle analysis by electron microscopy is a well established technique for analyzing the three-dimensional structures of biological macromolecules. Besides its ability to produce high-resolution structures, it also provides insights into the dynamic behavior of the structures by elucidating their conformational variability. Here, the different image-processing methods currently available to study continuous conformational changes are reviewed.


Assuntos
Elétrons , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Imageamento Tridimensional/estatística & dados numéricos , Substâncias Macromoleculares/ultraestrutura , Microscopia Eletrônica/métodos , Proteínas/ultraestrutura , Algoritmos , Humanos , Substâncias Macromoleculares/química , Microscopia Eletrônica/instrumentação , Conformação Molecular , Simulação de Dinâmica Molecular , Análise de Componente Principal , Proteínas/química , Termodinâmica
15.
J Struct Biol ; 204(3): 457-463, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30296492

RESUMO

Three dimensional electron microscopy is becoming a very data-intensive field in which vast amounts of experimental images are acquired at high speed. To manage such large-scale projects, we had previously developed a modular workflow system called Scipion (de la Rosa-Trevín et al., 2016). We present here a major extension of Scipion that allows processing of EM images while the data is being acquired. This approach helps to detect problems at early stages, saves computing time and provides users with a detailed evaluation of the data quality before the acquisition is finished. At present, Scipion has been deployed and is in production mode in seven Cryo-EM facilities throughout the world.


Assuntos
Microscopia Crioeletrônica/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Software , Algoritmos , Biologia Computacional/métodos , Reprodutibilidade dos Testes
16.
J Struct Biol ; 204(2): 329-337, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30145327

RESUMO

The Map Challenge organized by the Electron Microscopy Data Bank has prompted the development of an Xmipp high resolution reconstruction protocol (which we will refer to as highres) that is integrated in the software platform Scipion. In this work we describe the details of the image angular alignment and map reconstruction steps in our new method. This algorithm is similar to the standard projection matching approach with some important modifications, especially in the area of detecting significant features in the reconstructed volume. We show that the new method is able to produce higher resolution maps than the current de facto standard as measured by the Fourier Shell Correlation, the Monogenic Local Resolution and EMRinger.


Assuntos
Microscopia Eletrônica/métodos , Algoritmos , Software
17.
J Struct Biol ; 203(2): 90-93, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29551714

RESUMO

The introduction of Direct Electron Detector (DED) videos in the Electron Microscope field has boosted Single Particle Analysis to a point in which it is currently considered to be a key technique in Structural Biology. In this article we introduce an approach to estimate the DED camera gain at each pixel from the movies themselves. This gain is needed to have the set of recorded frames into a coherent gray level range, homogeneous over the whole image. The algorithm does not need any other input than the DED movie itself, being capable of providing an estimate of the camera gain image, helping to identify dead pixels and cases of incorrectly calibrated cameras. We propose the algorithm to be used either to validate the experimentally acquired gain image (for instance, to follow its possible change over time) or to verify that there is no residual gain image after experimentally correcting for the camera gain. We show results for a number of DED camera models currently in use (DE, Falcon II, Falcon 3, and K2).


Assuntos
Microscopia Eletrônica/métodos , Algoritmos , Microscopia Crioeletrônica , Processamento de Imagem Assistida por Computador , Fotografação
19.
Sci Rep ; 7(1): 6307, 2017 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-28740215

RESUMO

Single Particle Analysis using cryo-electron microscopy is a structural biology technique aimed at capturing the three-dimensional (3D) conformation of biological macromolecules. Projection images used to construct the 3D density map are characterized by a very low signal-to-noise ratio to minimize radiation damage in the samples. As a consequence, the 3D image alignment process is a challenging and error prone task which usually determines the success or failure of obtaining a high quality map. In this work, we present an approach able to quantify the alignment precision and accuracy of the 3D alignment process, which is then being used to help the reconstruction process in a number of ways, such as: (1) Providing quality indicators of the macromolecular map for soft validation, (2) Assessing the degree of homogeneity of the sample and, (3), Selecting subsets of representative images. We present experimental results in which the quality of the finally obtained 3D maps is clearly improved.

20.
Biomed Res Int ; 2017: 6482567, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29312997

RESUMO

One of the key steps in Electron Microscopy is the tomographic reconstruction of a three-dimensional (3D) map of the specimen being studied from a set of two-dimensional (2D) projections acquired at the microscope. This tomographic reconstruction may be performed with different reconstruction algorithms that can be grouped into several large families: direct Fourier inversion methods, back-projection methods, Radon methods, or iterative algorithms. In this review, we focus on the latter family of algorithms, explaining the mathematical rationale behind the different algorithms in this family as they have been introduced in the field of Electron Microscopy. We cover their use in Single Particle Analysis (SPA) as well as in Electron Tomography (ET).


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Microscopia Eletrônica/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...